Gemini®
DOUBLE CAMBERED PLAIN TILE APPEAL AT PITCHES DOWN TO 22.5º

NEW DESIGN BENEFITS
- Increased Tile Strength
- Even Stronger, Tighter interlock
- Improved coverage (less tiles per m²)
- Outstanding Aesthetic Appeal
- 40% less CO2 emissions per m2 roof
- The Decent Homes Solution
MAIN FEATURES
- Traditional Plain Tile appearance
- Lays to lower pitches - 22.5º (35º for plain tiles)
- Only 16.3 tiles per m² (60 for plain tiles)
- Hidden Fixings
- Full range of Dry Fix fittings
- Available in 10 colours including the new Black
- Kitemarked to BS EN 490
- 60 year guarantee
For all sales enquiries please contact our Customer Service office at Leighton Buzzard

FIXING: Nail once. (Aluminium Nail 45mm x 3.35mm). The nail hole diameter is approximately 5mm, with the hole being positioned approximately 37mm down from the head of the tile and 58 mm in from the right hand edge of the tile. In all circumstances, verges should be clipped. A plastic clip is available to enable secure fixing in exposed locations. It is a fixing requirement that the second course of slates is nailed and clipped in all cases, to secure the eaves course. In sheltered locations variations on the fixing specifications may be used, but should not be attempted without consultation with the Forticrete Technical Advisory Service. Forticrete will be pleased to provide written fixing specifications for specific projects as they cannot be held responsible for fixings on projects where their own guidelines are not followed correctly.
FIXING OF GEMINI TILE CLIP: The Gemini Tile Clip is not mechanically fixed to the batten, but clips on to the tile interlock (at point A). The clip is then slid down (to point B) and the curved underlock (C) locates under the back of the tile below (D).
| Pitch | Headlap | Batten Spacing | Batten Required | Tiles Required | Mass(approx) |
|---|---|---|---|---|---|
| 22.5-29º | 80mm min | 190mm max | 5.26 lin m/m² | 16.6/m² | 47kg/m² |
| 95mm max | 175mm min | 5.70 lin m/m² | 18.1/m² | 51kg/m² | |
| 30-70º | 75mm min | 195mm max | 5.13 lin m/m² | 16.3/m² | 45kg/m² |
| 95mm max | 175mm min | 5.70 lin m/m² | 18.1/m² | 51kg/m² |
Batten Size: 38mm x 25mm for spans up to 450mm; 50mm x 25mm for spans from 450mm up to 600mm in accordance with BS 5534:2003.
NB: the minimum pitch is based on a maximum rafter length of 10m. For rafter lengths greater than this, please contact the Forticrete Technical Advisory Service.
The table above shows the general fixing information for the Gemini tile, however for more detailed fixing requirements please refer to either the Zonal Fixing Method or alternatively you can request a fixing specification from the Technical Department using the downloadable form. For guidance on quantifying an roof with Gemini tiles - click here.

GUARANTEE: The colour of Gemini will change
with natural weathering over the years but the integrity of the
tiles carries a 60 year guarantee, from date of supply, subject to
the company's normal terms.
Forticrete Roofing Products' policy is one of continuous
improvement and the Company reserves the right to change
specifications and designs at any time without notice. The colours
reproduced within this website are as close as the
photographic processes will allow.
Where an exact colour match is critical, you are advised to
view actual tile samples.
To obtain samples either call our Leighton Buzzard office or complete the online form.
Forticrete has the ability to provide a range of associated fittings to complete your roof whether it is wet or dry fix.
- Eaves Detailing
- Undercloak Dry Verge
- Dry Hip - Third Round
- Dry Hip - Bonnet
- Mitred Hip
- Dry Ridge - Ridgeboard
- Dry Ridge - Trussed Rafter
- Mono Pitch Dry Ridge
- Gas Vent Ridge Terminal
- Soil Vent Ridge Terminal
- Abutment Ventilation
- In-Line Ventilation
Standard Components:
Download various related CAD details here:
Recent Projects completed using Gemini;
- Wolverhampton Re-roofing Project
- Persimmon Homes, nr Selby
- Wibb Builders, Alfreton
- Wolverhampton Cricket Club
- Charles Church Homes, Yarm
|
|
Fixing Specification & Take-off Request Form (32 KB) | Click here to download |
|
|
Gemini Zonal Fixing Method (Tables only) (86 KB) | Click here to download |
|
|
How to Quantify a Gemini Roof (35 KB) | Click here to download |
|
|
Half Round Ridge (134 KB) | Click here to download |
|
|
Third Round Ridge (104 KB) | Click here to download |
|
|
Universal Angle Ridge (98 KB) | Click here to download |
|
|
Dry Fix & Ventilation Brochure - April 2007 (4 MB) | Click here to download |
|
|
Gemini 6 Page Brochure - May 2007 (892 KB) | Click here to download |
|
|
Gemini Autumn 2 page brochure (819 KB) | Click here to download |
|
|
Gemini Brindle 2 page brochure (871 KB) | Click here to download |
|
|
Gemini Jacobean 2 page brochure (858 KB) | Click here to download |
|
|
Gemini Mixed Russet 2 page brochure (847 KB) | Click here to download |
|
|
Gemini Sunrise Blend 2 page brochure (796 KB) | Click here to download |
|
|
Design Guide (868 KB) | Click here to download |
|
|
Gemini 2 Page brochure - July 2008 (434 KB) | Click here to download |
|
|
COSHH Data Sheet - Roofing (2008) (46 KB) | Click here to download |
![[logo] Forticrete](gfx/logo_forticrete.gif)


![[logo] Forticrete](gfx/logo_forticrete_footer.gif)
![[logo] Fivesite](gfx/logo_fivesite.gif)