I am designing a Stack Bonded wall. Do I need to take any additional action?

[icon] - Answer

The lack of cross bonding from the block directly above or below each unit will affect the flexural strength of the panel considerably. Experience has shown that bed joint reinforcement should be included at every other course (450mm centres) for the full height and width of the panel.