Thermal
The new Part L Building Regulations (Conservation of Fuel and
Power) came into force on 6th April 2006 in England and Wales,
superseding the 2002 edition. The improvements in the Regulations
have mainly been driven by the Energy Performance of Buildings
Directive (EPBD) which came into force in January 2006. The EPBD
dictates that a key requirement for each new building is to have an
overall energy performance target.
The Part L changes will improve the energy efficiency of new houses
and other dwellings so that less fuel will be consumed to keep the
house at a comfortable temperature. Part L, which sets out the
legal requirements for the conservation of fuel and power in
buildings, has now been subdivided into 4 sections:-
- Part L1A - work in new dwellings
- Part L1B - work in existing dwellings
- Part L2A - new buildings other than dwellings
- Part L2B - work in existing buildings that are not dwellings
As part of the changes to the Building Regulations, under Criterion 2 - Limits on Design Flexibilty, an upper limit has been set for construction elements within a dwelling;
- Walls - 0.35W/mēK
- Roofs - 0.25W/mēK
- Floors - 0.25W/mēK
- Windows, Doors - 2.2W/mēK
Although u-values are no longer a means of complying with Part L
of the building regulations they still play a part in the SAP
calculation required for the property. Forticrete's Technical
department has the ability to carry out U-value calculations should
you require or alternatively the CBA has a simple calculator on its
website - click here.
For details please call 0800 262136 or
alternatively email technical@forticrete.com.
If you require a full SAP calculation, our sister company
Springvale offers this service - www.sapsonline.com
Partial Fill Option
| Layer | Thickness mm | K | R |
|---|---|---|---|
| External Surface Resistance | 0.040 | ||
| Brick Outer Leaf | 102.5 | 0.770 | 0.133 |
| Cavity |
50 |
0.078 | 0.440 |
| Ecotherm Cavity Wall | 50 | 0.023 | 2.174 |
| Forticrete Newlite | 100 | 0.43 | 0.233 |
| Airspace - dabs | 10 | 0.067 | 0.150 |
| Plasterboard | 12.5 | 0.210 | 0.060 |
| Internal Surface Resistance | 0.130 |
U-VALUE = 0.30W/mēK
Full Fill Option
| Layer | Thickness mm | K | R |
|---|---|---|---|
| External Surface Resistance | 0.040 | ||
| Brick Outer Leaf | 102.5 | 0.770 | 0.133 |
| Springvale Platinum Ecobead | 100 | 0.033 | 3.030 |
| Forticrete Newlite | 100 | 0.43 | 0.233 |
| Airspace - dabs | 10 | 0.067 | 0.150 |
| Plasterboard | 12.5 | 0.210 | 0.060 |
| Internal Surface Resistance | 0.130 |
U-VALUE = 0.26W/mēK
| Related Documents | ||
|---|---|---|
|
|
Meeting the Needs of Part L - Guidance Document (454 KB) | Click here to download |